Sammeln Setup als Titelseite Suchen

Multifunction network analyzer    Bestell-Nr:

Anfrage sendung

Bitte füllen sie die Details und sagen Sie mir das Ursprungsland, die Markenname und alle Informationen, die Sie schon erhalten. Das wird uns helfen, schnell zu angeboten. Vielen dank!

Marke(Manutacturer)*

Firmenname*

Produktname(Product Name)*

Modell*

Produktmodell(Product Type)*

Adresse*

Seriennummer(ID-Nr;Artikel-Nr)

Telefon*

Beschreibung(Voltage,Amp,Kw,Rpm)

Fax*

Menge(Quantity demanded)

E-mail*

Details

Multifunction network analyzer

 
 
 

 

 
 
 

 

The advantages are clear

The cost is comparable to any other simple multifunction device but it has better initial features (graphic display, pulsed outputs for power taken, short storage of consumption levels in log) plus it can be transformed into a true Power Quality instrument without having to replace it. Create your X-Meter whenever and however you want. Check the list for all of the possible options.

  • Bidirectional Meter (Imported/delivered power)
  • 50 true measurements
  • Measurements in true value (true RMS)
  • Measurements on 4 quadrants
  • Graphic display, size of characters can be set
  • Full and clear indications of measurements
  • 6-key keyboard with buzzer
  • Configurable pulsed outputs of all measured quantities
  • Configurable alarm outputs of measured quantities
  • Graphic display of Voltage, Current, Power and COSƒ for the last 3 days
  • 12 Power Totalizators on 4 quadrants that can be reset using a password
  • Indication in Euros of absorbed and delivered power
  • Clock and Calendar
  • Container of DIN rail 46277 (9 modules)
  • Removable clamps to make installation easier
  • Temperature probe inside the instrument
  • Software TA and TV inversion function
  • Expansion and modularity (memory, digital inputs, GSM/GPRS modem, Ethernet, e-mail, quality of supply)

 

Available Options

 

  • XM1 – Memory Extension and Communication
To interface the device to the Es3 software, it is necessary to enable this function. This option allows for a considerable increase in storage capacity, allowing the device to record all of the values measured by the instrument and to extend the memory capacity of the recordable days, up to an archive of 250 days. (Integration time of 15′ for the following values: line voltage and phase voltage, three-phase line current, three-phase active power, three-phase reactive power, three-phase power factor). Furthermore, by enabling the RS485 communication port through which it is possible to use a Personal Computer through a BRIDGE module (not included), it is possible to connect a series of EnergyTeam devices.
  aaa

 

 

  • XM2 Bridge Module A 232/485 – Bridge Module USB/485 B
The Bridge 232/485 conversion module with 230Vac power supply in 4 DIN module container, can be used to convert the 485 signal coming from the X-Meter in 232 serial towards the communication port of the Personal Computer. USB/485 version also available. The module can be used to convert the 485 signal coming from the X-Meter to the USB port on a Personal Computer. Galvanic isolation of the USB connection ensures maximum protection of the PC from disturbances or voltage surges coming from the field. Designed with industrial features. No bulky external power supply is needed as it is self-powered. One of a kind.

 

  • XM3 – 8 Digital inputs Module
Module with 8 self-powered digital inputs at 12Vdc. It can be used for the acquisition of conditions and pulses coming from external meters such as those for gas, water, air, etc. Furthermore, it is possible to separately archive the various acquisition channels by checking the logs using the specific software (not included). This function is possible with at least the XM1 function enabled.

 

  • XM4 – GSM/GPRS Module meter
The GSM/GPRS modem inside the X-Meter device allows for the sending of emails and SMS associated with conditions and alarms coming from the “field”, connected with the XM3 function (Module 8 digital inputs). Furthermore, thanks to this module, it is possible to control the X-Meter device remotely for the online data publication service through our website, www.energyteam.it. Our site can be accessed at anytime, anywhere with a userid and password. The displayed data can also be converted into Excel and Access format and downloaded to your PC. This function is possible with at least the XM1 function enabled..

 

aaaa
  • XM5 – Ethernet Module
The Ethernet card inside the device allows X-Meter to be connected to the corporate Ethernet or intranet from various data collection and monitoring stations through a simple IP address. This function is possible only with the XM1 functions and Es3 software enabled.

 

aa
  • XM6 – Harmonics Recording Module
Module for harmonic measurements which allows for the measurement and storage function up to the 25th measurement.

 

  • XM7 – Annual programmable clocks Module
The “programmable clocks with perpetual annual calendar” firmware module is used to enable the 4 Optomos outputs on the X-Meter DIN for the automatic control function to switch specific utilities on and off (controllable loads e.g., lights, motors, fans, etc.). Each X-Meter can be programmed with up to 12 daily profiles +profiles 2 special periods + 20 special days. Each profile defines 8 conditions changes within the 24 hours per day for each of the 4 associated loads. Up to 128 X-Meters can be connected for a total of 512 controllable loads. This function is possible only with the XM1 function enabled.

 

  • XM8 – Galvanically Insulated Analogical Channel
Inserted in a 1 Mod. DIN containers, it allows for the interfacing of voltage or current signals coming from the field to the X-Meter device inputs, allowing the display and storage of the measured values. The X-Meter device is able to power up to 2 XM8 modules. Any additional modules must be supported through a 12Vdc power supply (not included). There are 11 possible interface configurations for voltage and current signals. Guaranteed precision of 0.5% of the full scale.

 

  • XM9 – Module for Interfacing probes PT100-500-1000
Inserted in a 1 Mod. DIN container, it allows for the interfacing of PT100, PT500 and PT1000 temperature probes at the inputs of the X-Meter device, enabling the display and storage of the measured temperatures. The X-Meter device is able to power up to 2 XM8 modules. Any additional modules must be supported through a 12Vdc power supply (not included). Guaranteed precision at0.5 % of full scale.

 

  • XM10 – Room temperature Module
Container suitable for wall installation. It can read the room temperature (range -10 °C +65°C +- 1.5°C) and transfer it to the XMETER device inputs, thus enabling the displaying and storing of the temperatures measured. The X-Meter device is able to power up to 2 XM10 modules. Any additional modules must be supported through a 12Vdc power supply (not included). It is particularly suitable to monitor and save the room temperatures in Ced, LV/MV panels, Warehouses.

 

  • XM11 – Room temperature and humidity Module
Container suitable for wall installation. It can read the room temperature and humidity and transfer it to the XMETER device inputs thus enabling the displaying and storing of the temperatures and humidity values measured. The X-Meter device is able to power up to 2 XM11 modules. Any additional modules must be supported through a 12Vdc power supply (not included). It is particularly suitable to monitor and save room temperatures and humidity values in the food industry. Humidity Range (Relative Hum 0-100%) Accuracy ±2% in the range of rel. hum. 10% 90% Temp Range (-10°C +65°C) Accuracy ±0,8°C to 25°C ±0.3°C.

 

  • XM12 – USB/GSM Modem
The GSM modem for remote reading of data and remote programming is easy to connect to a PC thanks to the integrated USB connection.
  • XM14 – Power Quality
Module for recording voltage peaks and values with 10 ms resolution. It can also measure and store up to the 25th harmonic, both voltage and current. A local alarm can be enabled when the event occurs, set in advance.

 

  • XM15 – Load interface relay Module
To use the 4 outputs to drive standard loads in a 220Vac single phase network, they must be interfaced to the XM15 module. With 220Vac, it makes 4 completely independent relays available with the ability to switch any load up to 16A.

 

  • XM18 – Load management module
Through the control of the 4 outputs carried out using a sophisticated algorithm, it is possible to actively intervene in the management of electrical loads in order to eliminate or minimize exceeding the power contracted with the energy supplier.
  • XM UpS – Dedicated DIN UpS
Extremely small backup power supply in 6 DIN module container with cutting edge batteries (lithium polymer) to supply an X-Meter device for up to a maximum of one hour.